AM2302B/DHT22 Digital Temperature and Humidity Sensor Module

Combined temperature and humidity sensor module with a calibrated digital output and single-bus interface. The AM2302B/DHT22 product description identifies capacitive humidity sensing and an integrated temperature-measurement element for environmental data collection.

Product details

AM2302B Temperature and Humidity Sensor Module

AM2302 Temperature and Humidity Sensor

The AM2302B humidity-sensitive capacitor digital temperature and humidity module is a combined temperature and humidity sensor with calibrated digital signal output. It applies dedicated digital module acquisition technology and temperature and humidity sensing technology to ensure the product has extremely high reliability and excellent long-term stability. The sensor includes a capacitive humidity-sensing element and a high-precision temperature-measuring element, connected to a high-performance 8-bit microcontroller. Therefore, this product has advantages such as excellent quality, ultra-fast response, strong anti-interference capability, and extremely high cost performance. Each sensor is calibrated in an extremely precise humidity calibration room. Calibration coefficients are stored in the microcontroller in program form, and these calibration coefficients must be called during the internal processing of detection signals by the sensor. The standard single-bus interface makes system integration simple and fast. With ultra-small size and extremely low power consumption, the signal transmission distance can reach over 20 meters, making it suitable for various applications and demanding application scenarios. The product uses 3 wires (single-bus interface) for convenient connection.

Specifications
Name AM2302B Temperature and Humidity Module
Supply Voltage (Vin) DC3.3-5.5 V
Output Signal Single-bus digital signal
Display Resolution 0.1 °C or 0.1% RH
Temperature Detection Range -40-80℃
Humidity Detection Range 0-99.9%RH
Humidity Detection Accuracy ±2%RH
Temperature Detection Accuracy ±0.5℃
Acquisition Cycle 1/e(63%)<5s
Storage Temperature Range 0-80℃
Storage Humidity Range Below 95% RH (non-condensing)
Product Net Weight 1g
Product Shell Material PC Plastic
AM2302B/DHT22 Digital Temperature and Humidity Sensor Module — sensor module mechanical dimensions
AM2302B/DHT22 Digital Temperature and Humidity Sensor Module — temperature humidity sensor cable
AM2302B/DHT22 Digital Temperature and Humidity Sensor Module — sensor cable pinout
AM2302B/DHT22 Digital Temperature and Humidity Sensor Module — sensor with lcd display

Working and Storage Conditions

Exceeding the recommended operating range of the sensor may result in temporary drift signals of up to 3% RH. After returning to normal operating conditions, the sensor will slowly recover towards its calibrated state. To accelerate the recovery process, refer to "Recovery Treatment". Prolonged use under non-normal operating conditions will accelerate product aging.

Effects of exposure to chemicals

The sensing layer of a capacitive humidity sensor is susceptible to interference from chemical vapors. The diffusion of chemicals into the sensing layer can lead to measurement drift and decreased sensitivity. In a clean environment, contaminants will slowly be released. The recovery process described below will accelerate this. High concentrations of chemical contamination (such as ethanol) can cause permanent damage to the sensor's sensing layer.

Temperature effect

The relative humidity of a gas depends largely on temperature. Therefore, when measuring humidity, the humidity sensor should be operated at the same temperature as much as possible. If it shares a printed circuit board with heat-generating electronic components, during installation, the sensor should be placed as far away from the electronic components as possible and installed below the heat source, while maintaining good ventilation of the enclosure. To reduce heat conduction, the copper plating between the sensor and other parts of the printed circuit board should be minimized, and a gap should be left between them.

Precautions for Wiring and Welding under Light Influence

Long-term exposure to sunlight or intense ultraviolet radiation will degrade performance.

The quality of signal cables affects the quality of voltage output; high-quality shielded cables are recommended.

For manual soldering, contact time must be less than 3 seconds at a maximum temperature of 300 °C.

Recovery Processing

Sensors placed under extreme operating conditions or in chemical vapors can be restored to their calibrated state through the following procedure. Maintain at 45 °C and <10%RH humidity for 2 hours (drying); then maintain at 20-30 °C and >70%RH humidity for more than 5 hours.

Sensor Performance

5.1 Relative Humidity

Product details 2
Parameter Condition min typ max Unit
Resolution 0.1 %RH
16 bit
Accuracy (1) 25℃ ± 2 %RH
Repeatability ± 0.3 %RH
Interchangeability Fully interchangeable
Response time (2) 1/e(63%) <5 S
Hysteresis <0.3 %RH
Drift* Typical value <0.5 %RH/yr

Electrical Characteristics

Electrical characteristics, such as power consumption, high and low levels, input and output voltages, etc., all depend on the power supply. Table 4 details the electrical characteristics of the AM2302; if not specified, it indicates a supply voltage of 5 V. To achieve optimal performance with the sensor, please strictly adhere to the conditions in Table 4 during design.

Product details 3
Parameter Condition min typ max Unit
Supply Voltage 3.5 5 5.5 V
Power Consumption [a] Sleep 10 µA
Measurement 500 µA
Average 300 µA
Low-level Output Voltage IOL[b] 0 300 mV
High-level Output Voltage Rp<25 kΩ 90% 100% VDD
Low-level Input Voltage Falling 0 30% VDD
High-level Input Voltage Rising 70% 100% VDD
Rpu[c] VDD = 5 V
VIN = VSS
30 45 60 kΩ
Output Current Open 8 mA
Tri-state (Off) 10 20 µA
Sampling Period 2 S

Single-bus communication (ONE-WIRE)

Typical circuit of 1-Wire

The typical application circuit for connecting the microprocessor to the AM2302 is shown in Figure 4. In single-bus communication mode, SDA is pulled up and then connected to the I/O port of the microprocessor.

Special notes on single-bus communication:

1. In the typical application circuit, it is recommended to use a 5.1K pull-up resistor when the connection line length is shorter than 30 meters; when it is longer than 30 meters, reduce the resistance value of the pull-up resistor according to the actual situation.

2. When powered by 3.3 V voltage, the connection line length must not exceed 30 cm. Otherwise, the voltage drop on the line will cause insufficient power supply to the sensor, resulting in measurement deviation.

3. The minimum interval time for reading the sensor is 2S; if the reading interval is less than 2S, it may lead to inaccurate temperature and humidity readings or unsuccessful communication.

4. Each readout of temperature and humidity values is the result of the previous measurement. To obtain real-time data, two consecutive reads are required. It is recommended to read the sensor multiple times consecutively, with an interval greater than 2 seconds between each read, to obtain accurate data.

View full details