{"product_id":"am2302bdht22-single-bus-digital-temperature-and-humidity-sensor-module-probe-am2302switchboard","title":"AM2302B(DHT22)\/Single-bus digital temperature and humidity sensor module probe AM2302Switchboard","description":"\u003cstyle data-detail-image-cleanup=\"1\"\u003e.aurum-product-description img.detail-image{width:auto!important;max-width:100%;height:auto!important;object-fit:contain}.aurum-product-description .detail-block:empty,.aurum-product-description .detail-group:empty,.aurum-product-description .detail-grid:empty{display:none!important;margin:0!important;padding:0!important;min-height:0!important}\u003c\/style\u003e\u003cstyle\u003e\n.aurum-product-description{max-width:1000px;margin:0 auto;color:#17212b;line-height:1.7;overflow-wrap:anywhere}\n.aurum-product-description *{box-sizing:border-box}\n.aurum-product-description h1{line-height:1.25;margin:0 0 18px;font-weight:700}\n.aurum-product-description h2{line-height:1.35;margin:30px 0 14px}\n.aurum-product-description h3{line-height:1.4;margin:24px 0 12px}\n.aurum-product-description p{margin:0 0 14px;white-space:normal}\n.aurum-product-description ul,.aurum-product-description ol{padding-left:24px;margin:12px 0 20px}\n.aurum-product-description li{margin:7px 0}\n.aurum-product-description .seo-overview,.aurum-product-description .seo-recovered{padding:20px clamp(12px,3vw,28px)}\n.aurum-product-description .seo-summary{line-height:1.65;color:#34495e}\n.aurum-product-description .seo-details-heading{padding:0 clamp(12px,3vw,28px)}\n.aurum-product-description .detail-block,.aurum-product-description .detail-cell,.aurum-product-description .detail-page,.aurum-product-description .detail-group,.aurum-product-description .detail-flow,.aurum-product-description .detail-grid{display:block;width:100%;min-width:0;max-width:100%;height:auto;margin:0;container-type:normal}\n.aurum-product-description .detail-text,.aurum-product-description .detail-table{padding:16px clamp(12px,3vw,28px);background:#fff}\n.aurum-product-description img{display:block;max-width:100%;height:auto;margin:12px auto 24px}\n.aurum-product-description .detail-image{max-width:100%;height:auto}\n.aurum-product-description .seo-table-scroll{max-width:100%;overflow-x:auto;margin:12px 0 24px;overscroll-behavior-x:contain}\n.aurum-product-description .seo-table-scroll:focus-visible{outline:2px solid #275f92;outline-offset:3px}\n.aurum-product-description table{border-collapse:collapse;width:100%;table-layout:auto;line-height:1.6}\n.aurum-product-description caption{text-align:left;font-weight:700;padding:0 0 10px;color:#17212b}\n.aurum-product-description th,.aurum-product-description td{border:1px solid #c9d0d8;padding:11px 14px;vertical-align:top;white-space:pre-line;overflow-wrap:normal;word-break:normal}\n.aurum-product-description thead th{background:#eaf0f6;text-align:left;font-weight:700}\n.aurum-product-description tbody th{background:#f4f7fa;text-align:left;font-weight:600}\n.aurum-product-description tbody tr:nth-child(even) td{background:#fafbfd}\n.aurum-product-description a{color:#185686;text-decoration:underline;text-underline-offset:3px}\n@media(max-width:600px){.aurum-product-description table{}.aurum-product-description th,.aurum-product-description td{padding:9px 10px}.aurum-product-description h2{}.aurum-product-description .seo-summary{}}\n@media print{.aurum-product-description{max-width:100%}.aurum-product-description .seo-table-scroll{overflow:visible}.aurum-product-description tr{break-inside:avoid}}\n\u003c\/style\u003e\n\u003cdiv class=\"product-detail aurum-product-description\" data-image-seo-version=\"1\" data-seo-version=\"2\"\u003e\n\u003csection class=\"seo-overview\"\u003e\u003ch2\u003eAM2302B\/DHT22 Digital Temperature and Humidity Sensor Module\u003c\/h2\u003e\n\u003cp class=\"seo-summary\"\u003eCombined temperature and humidity sensor module with a calibrated digital output and single-bus interface. The AM2302B\/DHT22 product description identifies capacitive humidity sensing and an integrated temperature-measurement element for environmental data collection.\u003c\/p\u003e\u003c\/section\u003e\u003csection aria-label=\"Product details\" class=\"seo-original-content\"\u003e\u003ch3 class=\"seo-details-heading\"\u003eProduct details\u003c\/h3\u003e\n\u003csection\u003e\u003cp\u003eAM2302B Temperature and Humidity Sensor Module\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eAM2302 Temperature and Humidity Sensor\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eThe AM2302B humidity-sensitive capacitor digital temperature and humidity module is a combined temperature and humidity sensor with calibrated digital signal output. It applies dedicated digital module acquisition technology and temperature and humidity sensing technology to ensure the product has extremely high reliability and excellent long-term stability. The sensor includes a capacitive humidity-sensing element and a high-precision temperature-measuring element, connected to a high-performance 8-bit microcontroller. Therefore, this product has advantages such as excellent quality, ultra-fast response, strong anti-interference capability, and extremely high cost performance. Each sensor is calibrated in an extremely precise humidity calibration room. Calibration coefficients are stored in the microcontroller in program form, and these calibration coefficients must be called during the internal processing of detection signals by the sensor. The standard single-bus interface makes system integration simple and fast. With ultra-small size and extremely low power consumption, the signal transmission distance can reach over 20 meters, making it suitable for various applications and demanding application scenarios. The product uses 3 wires (single-bus interface) for convenient connection.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cdiv class=\"grid\"\u003e\u003cdiv\u003e\u003csection\u003e\u003cdiv aria-label=\"Specifications\" class=\"seo-table-scroll\" role=\"region\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eSpecifications\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eName\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAM2302B Temperature and Humidity Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eSupply Voltage (Vin)\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC3.3-5.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSingle-bus digital signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eDisplay Resolution\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0.1 °C or 0.1% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eTemperature Detection Range\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-40-80℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eHumidity Detection Range\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0-99.9%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eHumidity Detection Accuracy\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e±2%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eTemperature Detection Accuracy\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eAcquisition Cycle\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1\/e(63%)＜5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eStorage Temperature Range\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0-80℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eStorage Humidity Range\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBelow 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eProduct Shell Material\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePC Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003cimg alt=\"AM2302B\/DHT22 Digital Temperature and Humidity Sensor Module — sensor module mechanical dimensions\" decoding=\"async\" height=\"319\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0845\/8761\/0365\/files\/am2302b-dht22-digital-temperature-and-humidity-sensor-module-sensor-module-mechanical-dimensions-01-2edcd14fbe-p15402216161533-r306550e9-cfe.webp?v=1793350722\" width=\"401\"\u003e\u003c\/section\u003e\u003csection\u003e\u003cimg alt=\"AM2302B\/DHT22 Digital Temperature and Humidity Sensor Module — temperature humidity sensor cable\" decoding=\"async\" height=\"390\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0845\/8761\/0365\/files\/am2302b-dht22-digital-temperature-and-humidity-sensor-module-temperature-humidity-sensor-cable-02-0952251f82-p15402216161533-r306550e9-cfe.webp?v=1793350723\" width=\"358\"\u003e\u003c\/section\u003e\u003csection\u003e\u003cimg alt=\"AM2302B\/DHT22 Digital Temperature and Humidity Sensor Module — sensor cable pinout\" decoding=\"async\" height=\"197\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0845\/8761\/0365\/files\/am2302b-dht22-digital-temperature-and-humidity-sensor-module-sensor-cable-pinout-03-481d9c7ab8-p15402216161533-r306550e9-cfe.webp?v=1793350722\" width=\"344\"\u003e\u003c\/section\u003e\u003csection\u003e\u003cimg alt=\"AM2302B\/DHT22 Digital Temperature and Humidity Sensor Module — sensor with lcd display\" decoding=\"async\" height=\"538\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0845\/8761\/0365\/files\/am2302b-dht22-digital-temperature-and-humidity-sensor-module-sensor-with-lcd-display-04-1eaf15c825-p15402216161533-r306550e9-cfe.webp?v=1793350722\" width=\"734\"\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eWorking and Storage Conditions\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eExceeding the recommended operating range of the sensor may result in temporary drift signals of up to 3% RH. After returning to normal operating conditions, the sensor will slowly recover towards its calibrated state. To accelerate the recovery process, refer to \"Recovery Treatment\". Prolonged use under non-normal operating conditions will accelerate product aging.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eEffects of exposure to chemicals\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eThe sensing layer of a capacitive humidity sensor is susceptible to interference from chemical vapors. The diffusion of chemicals into the sensing layer can lead to measurement drift and decreased sensitivity. In a clean environment, contaminants will slowly be released. The recovery process described below will accelerate this. High concentrations of chemical contamination (such as ethanol) can cause permanent damage to the sensor's sensing layer.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eTemperature effect\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eThe relative humidity of a gas depends largely on temperature. Therefore, when measuring humidity, the humidity sensor should be operated at the same temperature as much as possible. If it shares a printed circuit board with heat-generating electronic components, during installation, the sensor should be placed as far away from the electronic components as possible and installed below the heat source, while maintaining good ventilation of the enclosure. To reduce heat conduction, the copper plating between the sensor and other parts of the printed circuit board should be minimized, and a gap should be left between them.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003ePrecautions for Wiring and Welding under Light Influence\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eLong-term exposure to sunlight or intense ultraviolet radiation will degrade performance.\u003c\/p\u003e\n\u003cp\u003eThe quality of signal cables affects the quality of voltage output; high-quality shielded cables are recommended.\u003c\/p\u003e\n\u003cp\u003eFor manual soldering, contact time must be less than 3 seconds at a maximum temperature of 300 °C.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eRecovery Processing\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eSensors placed under extreme operating conditions or in chemical vapors can be restored to their calibrated state through the following procedure. Maintain at 45 °C and \u0026lt;10%RH humidity for 2 hours (drying); then maintain at 20-30 °C and \u0026gt;70%RH humidity for more than 5 hours.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eSensor Performance\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003e5.1 Relative Humidity\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cdiv aria-label=\"Product details 2\" class=\"seo-table-scroll\" role=\"region\" tabindex=\"0\"\u003e\u003ctable style=\"min-width:660px\"\u003e\n\u003ccaption\u003eProduct details 2\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003eCondition\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003emin\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003etyp\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003emax\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\" scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0.1\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003e16\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eAccuracy (1)\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e25℃\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e± 2\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e± 0.3\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eInterchangeability\u003c\/th\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFully interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eResponse time (2)\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1\/e(63%)\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u0026lt;5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eHysteresis\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u0026lt;0.3\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eDrift*\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTypical value\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u0026lt;0.5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e%RH\/yr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eElectrical Characteristics\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eElectrical characteristics, such as power consumption, high and low levels, input and output voltages, etc., all depend on the power supply. Table 4 details the electrical characteristics of the AM2302; if not specified, it indicates a supply voltage of 5 V. To achieve optimal performance with the sensor, please strictly adhere to the conditions in Table 4 during design.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cdiv aria-label=\"Product details 3\" class=\"seo-table-scroll\" role=\"region\" tabindex=\"0\"\u003e\u003ctable style=\"min-width:660px\"\u003e\n\u003ccaption\u003eProduct details 3\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003eCondition\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003emin\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003etyp\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003emax\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"col\"\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e5.5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"3\" scope=\"row\"\u003ePower Consumption [a]\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSleep\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e10\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eµA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e500\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eµA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eAverage\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e300\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eµA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eLow-level Output Voltage\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eIOL[b]\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e300\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003emV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eHigh-level Output Voltage\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eRp\u0026lt;25 kΩ\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e90%\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e100%\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eLow-level Input Voltage\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFalling\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30%\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eHigh-level Input Voltage\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eRising\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e70%\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e100%\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eRpu[c]\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVDD = 5 V\u003cbr\u003eVIN = VSS\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e30\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e45\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e60\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ekΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\" scope=\"row\"\u003eOutput Current\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOpen\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e8\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eTri-state (Off)\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e10\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e20\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eµA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" scope=\"row\"\u003eSampling Period\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e2\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eSingle-bus communication (ONE-WIRE)\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eTypical circuit of 1-Wire\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003cp\u003eThe typical application circuit for connecting the microprocessor to the AM2302 is shown in Figure 4. In single-bus communication mode, SDA is pulled up and then connected to the I\/O port of the microprocessor.\u003c\/p\u003e\n\u003cp\u003eSpecial notes on single-bus communication:\u003c\/p\u003e\n\u003cp\u003e1. In the typical application circuit, it is recommended to use a 5.1K pull-up resistor when the connection line length is shorter than 30 meters; when it is longer than 30 meters, reduce the resistance value of the pull-up resistor according to the actual situation.\u003c\/p\u003e\n\u003cp\u003e2. When powered by 3.3 V voltage, the connection line length must not exceed 30 cm. Otherwise, the voltage drop on the line will cause insufficient power supply to the sensor, resulting in measurement deviation.\u003c\/p\u003e\n\u003cp\u003e3. The minimum interval time for reading the sensor is 2S; if the reading interval is less than 2S, it may lead to inaccurate temperature and humidity readings or unsuccessful communication.\u003c\/p\u003e\n\u003cp\u003e4. Each readout of temperature and humidity values is the result of the previous measurement. To obtain real-time data, two consecutive reads are required. It is recommended to read the sensor multiple times consecutively, with an interval greater than 2 seconds between each read, to obtain accurate data.\u003c\/p\u003e\u003c\/section\u003e\u003c\/section\u003e\n\u003c\/div\u003e\n","brand":"AurumPCB","offers":[{"title":"AM2302B(DHT22)","offer_id":71482358792445,"sku":"744136235846_AM2302B(DHT22)_Sensor Module","price":3.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/8761\/0365\/files\/am2302b-dht22-digital-temperature-and-humidity-sensor-module-main-01-f709b4aa46-p15402216161533-r306550e9-cfe.jpg?v=1793494202","url":"https:\/\/4ys6gr-3t.myshopify.com\/products\/am2302bdht22-single-bus-digital-temperature-and-humidity-sensor-module-probe-am2302switchboard","provider":"AurumPcb","version":"1.0","type":"link"}